Kit (Small Direct Heat Exchanger): Difference between revisions
From Stationeers Wiki
More actions
→Description: minor typo |
Banangecko (talk | contribs) Overhauled page, triple structure box and simplified equation. |
||
| (One intermediate revision by one other user not shown) | |||
| Line 1: | Line 1: | ||
[[Category:Atmospherics]] | [[Category:Atmospherics]] [[Category:Heat Exchanger]] | ||
{{Itembox | {{Itembox | ||
| image = | | image = | ||
| Line 7: | Line 7: | ||
| stacks = Yes (10) | | stacks = Yes (10) | ||
| paintable = Yes | | paintable = Yes | ||
| constructs = '''Small Direct Heat Exchanger''' <br> (Gas + Gas, Liquid + Gas Liquid + Liquid) | |||
| prefabhash = -1332682164 | | prefabhash = -1332682164 | ||
| prefabname = ItemKitSmallDirectHeatExchanger | | prefabname = ItemKitSmallDirectHeatExchanger | ||
}} | }} | ||
{{ | {{Structurebox | ||
| image = [[File:Small direct heat exchanger gas to gas.png|in-game screenshot showing gas pipe inputs and meter]] | | image = | ||
| name = | |||
Small Direct Heat Exchanger - Gas + Gas | |||
[[File:Small direct heat exchanger gas to gas.png|in-game screenshot showing gas pipe inputs and meter]] | |||
<br><br> | |||
Small Direct Heat Exchanger - Liquid + Gas | |||
[[File:Small direct heat exchanger liquid to gas.png|in-game screenshot showing different pipe inputs and meter]] | |||
<br><br> | |||
Small Direct Heat Exchanger - Liquid + Liquid | |||
[[File:Small direct heat exchanger liquid to liquid.png|in-game screenshot showing liquid pipe inputs and meter]] | |||
| prefab_hash = Varies | |||
| prefab_name = Varies | |||
| placed_with_item = '''Kit (Small Direct Heat Exchanger)''' | |||
| placed_on_grid = Small Grid | |||
| requires_frames = No | |||
| | | decon_with_tool1 = [[Hand Drill]] | ||
| | |||
| | |||
}} | }} | ||
==Description== | ==Description== | ||
Exchanges heat between two pipe networks. It's next upgrade is the [[Kit (Large Direct Heat Exchanger)| Large Direct Heat Exchanger]]. <br> | <blockquote><q> Direct Heat Exchangers equalize the temperature of the two input networks. </q><br> | ||
'''- Stationpedia'''</blockquote> | |||
Exchanges heat between two pipe networks. It's next upgrade is the [[Kit (Large Direct Heat Exchanger)|Large Direct Heat Exchanger]]. <br> | |||
==Usage== | ==Usage== | ||
The kit produces 3 versions, gas to gas, liquid to gas and liquid to liquid. Each version has 2 pipe connections for pipe atmospheres whose contents' heat will be exchanged. The heat exchanger itself does not have an internal volume and instead acts directly on the input pipe networks. A meter on the side displays the heat exchange rate in joules (per tick | The kit produces 3 versions, gas to gas, liquid to gas and liquid to liquid. Each version has 2 pipe connections for pipe atmospheres whose contents' heat will be exchanged. The heat exchanger itself does not have an internal volume and instead acts directly on the input pipe networks. A meter on the side displays the heat exchange rate in joules (per tick). | ||
==Heat Exchange== | |||
Heat flows from hot to cold, flowing faster the greater the temperature difference. For small heat exchangers the rate will follow 100 joules/tick per degree celcius of difference. | |||
== Notes == | == Notes == | ||
* Can be placed in any orientation | |||
* Gas in the pipe does not need to be flowing to exchange heat effectively. Stationeers treats each pipe network as one object, so cooling one end of a pipe will immediately cool everywhere else in the pipe. | |||
=== Prefab Information === | |||
{| class="wikitable" | |||
|- | |||
! !! Prefab Hash !! Prefab Name | |||
|- | |||
| Gas + Gas || 1310303582 || StructureSmallDirectHeatExchangeGastoGas | |||
|- | |||
| Liquid + Gas || 1825212016 || StructureSmallDirectHeatExchangeLiquidtoGas | |||
|- | |||
| Example || -507770416 || StructureSmallDirectHeatExchangeLiquidtoLiquid | |||
|} | |||
Latest revision as of 08:51, 6 February 2026
| Constructing Options |
Small Direct Heat Exchanger (Gas + Gas, Liquid + Gas Liquid + Liquid) |
|---|---|
| Properties | |
| Stacks | Yes (10) |
| Paintable | Yes |
| Recipe | |
| Created With | Hydraulic Pipe Bender |
| Cost | 5g Copper, 3g Steel |
| Logic | |
| Item Hash | -1332682164 |
| Item Name | ItemKitSmallDirectHeatExchanger |
| Operation | |
|---|---|
| Prefab Hash | Varies |
| Prefab Name | Varies |
| Construction | |
| Placed with | Kit (Small Direct Heat Exchanger) |
| Placed on | Small Grid |
| Requires Frame | No |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
Description
Direct Heat Exchangers equalize the temperature of the two input networks.
- Stationpedia
Exchanges heat between two pipe networks. It's next upgrade is the Large Direct Heat Exchanger.
Usage
The kit produces 3 versions, gas to gas, liquid to gas and liquid to liquid. Each version has 2 pipe connections for pipe atmospheres whose contents' heat will be exchanged. The heat exchanger itself does not have an internal volume and instead acts directly on the input pipe networks. A meter on the side displays the heat exchange rate in joules (per tick).
Heat Exchange
Heat flows from hot to cold, flowing faster the greater the temperature difference. For small heat exchangers the rate will follow 100 joules/tick per degree celcius of difference.
Notes
- Can be placed in any orientation
- Gas in the pipe does not need to be flowing to exchange heat effectively. Stationeers treats each pipe network as one object, so cooling one end of a pipe will immediately cool everywhere else in the pipe.
Prefab Information
| Prefab Hash | Prefab Name | |
|---|---|---|
| Gas + Gas | 1310303582 | StructureSmallDirectHeatExchangeGastoGas |
| Liquid + Gas | 1825212016 | StructureSmallDirectHeatExchangeLiquidtoGas |
| Example | -507770416 | StructureSmallDirectHeatExchangeLiquidtoLiquid |