Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Wall Cooler: Difference between revisions

From Stationeers Wiki
Adamkk03 (talk | contribs)
mNo edit summary
m Fix broken headlines from translation cleanup
 
(10 intermediate revisions by 7 users not shown)
Line 1: Line 1:
<languages/>
 
<translate>
 
[[Category:Machines]]
[[Category:Machines]]
{{Itembox
{{Itembox
Line 12: Line 12:
  | name            = Wall Cooler
  | name            = Wall Cooler
  | image            = [[File:{{#setmainimage:WallCooler.png}}]]
  | image            = [[File:{{#setmainimage:WallCooler.png}}]]
  | power_usage      = 5W
  | power_usage      = 10W idle + 1000W active
  | placed_with_item = [[Wall Cooler (Item)]]
  | placed_with_item = [[Wall Cooler (Item)]]
  | placed_on_grid  = Small Grid, On Frames
  | placed_on_grid  = Small Grid, On Frames
Line 19: Line 19:
}}
}}


==Description== <!--T:1-->
==Description==
Used to lower the temperature inside a room.
Used to lower the temperature inside a room.
It will flash an error if certain things are not present like:
It will flash an error if certain things are not present like:
* [[Pipe Radiator]]
* Coolant gas pipe
* Atmosphere in the room you're trying to cool
* Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
* gasses in the coolant pipe
* Gasses in the coolant pipe (At least 12.5 kpa)
 
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]]


==Usage== <!--T:2-->
==Usage==
Place the Wall Cooler and run some pipes to the place you want to vent the heat. Place a few Pipe radiators on the pipe, fill it with whatever gasmixture you want and start the machine, it will slowly lower the temperature.
Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.


<!--T:3-->
* Best coolant for now Water, but Pollutant aka X is more abundant.
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.


Line 69: Line 69:
| Required Power || ||
| Required Power || ||
|}
|}
</translate>

Latest revision as of 17:40, 8 March 2026

Wall Cooler
Properties
Stacks Yes (5)
Recipe
Created With Hydraulic Pipe Bender, Fabricator
Cost 3g Iron, 1g Gold, 3g Copper
Wall Cooler
Operation
Power Usage 10W idle + 1000W active
Construction
Placed with Wall Cooler (Item)
Placed on Small Grid, On Frames
Stage 1
Deconstruction
Deconstructed with Hand Drill
Item received Wall Cooler (Item)


Description

Used to lower the temperature inside a room. It will flash an error if certain things are not present like:

  • Coolant gas pipe
  • Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
  • Gasses in the coolant pipe (At least 12.5 kpa)

Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right.

Efficiency drop off

Usage

Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.

  • The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.


Data Network Properties

These are all Data Network properties of this device.

Data Parameters

These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).


Parameter Name Data Type Description
Lock
Setting Boolean Unused
On

Data Outputs

These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.

Output Name Data Type Description
Power
Error
Lock
Setting
Maximum
Ratio
On
Required Power