Wall Cooler: Difference between revisions
More actions
No edit summary |
m Fix broken headlines from translation cleanup |
||
| (3 intermediate revisions by 3 users not shown) | |||
| Line 1: | Line 1: | ||
[[Category:Machines]] | [[Category:Machines]] | ||
{{Itembox | {{Itembox | ||
| Line 12: | Line 12: | ||
| name = Wall Cooler | | name = Wall Cooler | ||
| image = [[File:{{#setmainimage:WallCooler.png}}]] | | image = [[File:{{#setmainimage:WallCooler.png}}]] | ||
| power_usage = | | power_usage = 10W idle + 1000W active | ||
| placed_with_item = [[Wall Cooler (Item)]] | | placed_with_item = [[Wall Cooler (Item)]] | ||
| placed_on_grid = Small Grid, On Frames | | placed_on_grid = Small Grid, On Frames | ||
| Line 19: | Line 19: | ||
}} | }} | ||
==Description== | ==Description== | ||
Used to lower the temperature inside a room. | Used to lower the temperature inside a room. | ||
It will flash an error if certain things are not present like: | It will flash an error if certain things are not present like: | ||
* | * Coolant gas pipe | ||
* Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low) | * Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low) | ||
* | * Gasses in the coolant pipe (At least 12.5 kpa) | ||
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]] | Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right. [[File:Cooler Graph.png|thumb|Efficiency drop off]] | ||
==Usage== | ==Usage== | ||
Place the Wall Cooler and run some pipes to the place you want to vent the heat. | Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe. | ||
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe. | * The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe. | ||
| Line 71: | Line 69: | ||
| Required Power || || | | Required Power || || | ||
|} | |} | ||
Latest revision as of 17:40, 8 March 2026
| Properties | |
|---|---|
| Stacks | Yes (5) |
| Recipe | |
| Created With | Hydraulic Pipe Bender, Fabricator |
| Cost | 3g Iron, 1g Gold, 3g Copper |
![]() | |
| Operation | |
|---|---|
| Power Usage | 10W idle + 1000W active |
| Construction | |
| Placed with | Wall Cooler (Item) |
| Placed on | Small Grid, On Frames |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Wall Cooler (Item) |
Description
Used to lower the temperature inside a room. It will flash an error if certain things are not present like:
- Coolant gas pipe
- Atmosphere in the room you're trying to cool (minimum is around 5-8kpa, not sure exactly, will flash an error if too low)
- Gasses in the coolant pipe (At least 12.5 kpa)
Game update 0.2.1783.8193 Changed the wall cooler where the efficiency drops as the temperature difference becomes too large. If the waste network becomes 100 degrees warmer than input, efficiency begins to drop until zero at 200 degrees. This is highlighted on the graph on the right.

Usage
Place the Wall Cooler and run some pipes to the place you want to store or vent the heat. Fill the coolant pipe with enough gas and start the machine, it will slowly lower the rooms temperature by transfering its heat to the coolant pipe.
- The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Lock | ||
| Setting | Boolean | Unused |
| On |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Power | ||
| Error | ||
| Lock | ||
| Setting | ||
| Maximum | ||
| Ratio | ||
| On | ||
| Required Power |
