Always-on circuit guide: Difference between revisions
From Stationeers Wiki
More actions
auto restart an always on circuit |
m Sunspots moved page Always-on-circuit to Always-on circuit guide |
||
| (2 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
This circuit will check a device - in this example a [[Wall Light]] - and restart it, if it will | This circuit will check a device - in this example a [[Wall Light]] - and restart it, if it will shut down / deactivate for a reason. | ||
<gallery> | <gallery> | ||
AlwaysOnCircuit.jpg|Full Visual with Settings | AlwaysOnCircuit.jpg|Full Visual with Settings | ||
</gallery> | |||
[[File:AlwaysOnCircuit.jpg|thumb]] | [[File:AlwaysOnCircuit.jpg|thumb]] | ||
== Trivia== | == Trivia== | ||
*This little thing was invented by user "Simoyd" in discord-chat "logic-ciruit-discussion" and needed | *This little thing was invented by user '''"Simoyd"''' in discord-chat "logic-ciruit-discussion" and needed and created by user "Raumfahrtdoc" | ||
*This is super useful to restart the [[Kit (Gas Generator)]] / [[Gas Generator]] | *This is super useful to restart the [[Kit (Gas Generator)]] / [[Gas Generator]] | ||
== Improved version == | |||
[[File:Improved Always-On-Circuit.png|thumb|Improved Always-On-Circuit using only two I/O and two processing units.|thumb]] | |||
Using the new [[Kit_(Logic_Processor)#Min.2FMax_Unit|Min/Max Unit]] as an OR gate and [[Kit_(Logic_Processor)#Compare_Unit|Compare unit]] as a (controlled) NOT gate, a much cheaper version is possible. Basically, it is a controlled clock that only runs when the device is off and otherwise stays at 1. The circuit can also be modified easily to make an always-off circuit (e.g. to auto-close doors), see table below. | |||
{| class="wikitable" | |||
|+ Circuit setup | |||
|- | |||
! Unit name || Unit type || Connector / Setting || Source / Value | |||
|- | |||
| reader || Logic Reader Unit || IN || '''device''' (whatever you want to control) | |||
|- | |||
| || || VAR || On (''Open'' for a door or switch) | |||
|- | |||
| max || Min/Max Unit || OPR || Greater (''Less'' for an always-off-circuit) | |||
|- | |||
| || || 1 (input 1) || reader | |||
|- | |||
| || || 2 (input 2) || compare | |||
|- | |||
| compare || Compare Unit || OUT || Equals (''NotEquals'' for an always-off-circuit) | |||
|- | |||
| || || 1 (input 1) || reader | |||
|- | |||
| || || 2 (input 2) || max | |||
|- | |||
| writer || Logic Writer || IN || max (''compare'' will also do) | |||
|- | |||
| || || OUT || '''device''' (whatever you want to control) | |||
|- | |||
| || || OUT VAR || On (''Open'' for a door or switch) | |||
|} | |||
Latest revision as of 17:37, 18 November 2019
This circuit will check a device - in this example a Wall Light - and restart it, if it will shut down / deactivate for a reason.
-
Full Visual with Settings

Trivia
- This little thing was invented by user "Simoyd" in discord-chat "logic-ciruit-discussion" and needed and created by user "Raumfahrtdoc"
- This is super useful to restart the Kit (Gas Generator) / Gas Generator
Improved version

Using the new Min/Max Unit as an OR gate and Compare unit as a (controlled) NOT gate, a much cheaper version is possible. Basically, it is a controlled clock that only runs when the device is off and otherwise stays at 1. The circuit can also be modified easily to make an always-off circuit (e.g. to auto-close doors), see table below.
| Unit name | Unit type | Connector / Setting | Source / Value |
|---|---|---|---|
| reader | Logic Reader Unit | IN | device (whatever you want to control) |
| VAR | On (Open for a door or switch) | ||
| max | Min/Max Unit | OPR | Greater (Less for an always-off-circuit) |
| 1 (input 1) | reader | ||
| 2 (input 2) | compare | ||
| compare | Compare Unit | OUT | Equals (NotEquals for an always-off-circuit) |
| 1 (input 1) | reader | ||
| 2 (input 2) | max | ||
| writer | Logic Writer | IN | max (compare will also do) |
| OUT | device (whatever you want to control) | ||
| OUT VAR | On (Open for a door or switch) |