Wall Cooler: Difference between revisions
From Stationeers Wiki
More actions
F1r3w4rr10r (talk | contribs) Update to use the new Structurebox syntax |
No edit summary |
||
| Line 29: | Line 29: | ||
<!--T:3--> | <!--T:3--> | ||
Best coolant for now | * Best coolant for now Water, but Pollutant aka X is more abundant. | ||
* The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe. | |||
</translate> | </translate> | ||
Revision as of 05:31, 31 July 2018
<languages/> <translate>
| Recipe | |
|---|---|
| Created With | Hydraulic Pipe Bender, Fabricator |
| Cost | 3g Iron, 1g Gold, 3g Copper |
![]() | |
| Operation | |
|---|---|
| Power Usage | 5W |
| Construction | |
| Placed with | Wall Cooler (Item) |
| Placed on | Small Grid, On Frames |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Hand Drill |
| Item received | Wall Cooler (Item) |
Description
Used to lower the temperature inside a room. It will flash an error if certain things are not present like:
- Pipe Radiator
- Atmosphere in the room your trying to cool
- gasses in the coolant pipe
Usage
Place the Wall Cooler and run some pipes to the place you want to vent the heat. Place a few Pipe radiators on the pipe, fill it with whatever gasmixture you want and start the machine, it will slowly lower the temperature.
- Best coolant for now Water, but Pollutant aka X is more abundant.
- The wall cooler works by removing 1000 Joules of energy/tick (2000J/s) from the atmosphere and adding it into its pipe.