Basic Chutes: Difference between revisions
More actions
thrying out populating recipe list from script |
F1r3w4rr10r (talk | contribs) Add logic properties |
||
| Line 14: | Line 14: | ||
== Description == | == Description == | ||
Used to transport items. | Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network. | ||
== Recipes ==<!--T:3--> | == Recipes ==<!--T:3--> | ||
{{Recipe | {{Recipe | ||
| Line 22: | Line 22: | ||
|{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}} | |{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}} | ||
}} | }} | ||
== Logic Properties == | |||
These are all logic properties of the devices. | |||
=== Chute Bin === | |||
==== Logic Parameters ==== | |||
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | |||
{| class="wikitable" | |||
|- | |||
! Parameter Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Opens the Chute Bin, when set to 1. Closes it, when set to 0. | |||
|- | |||
| On || Boolean || Turns the Chute Bin on, when set to 1. Turns it off, when set to 0. | |||
|} | |||
==== Logic Outputs ==== | |||
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| Power || Boolean || Returns whether the Chute Bin is turned on. (0 for off, 1 for on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.) | |||
|- | |||
| Open || Boolean || Returns whether the Chute Bin is open. (0 for closed, 1 for open) | |||
|- | |||
| Error || Boolean || Returns whether the Chute Bin is flashing an error. (0 for no error, 1 for flashing an error) | |||
|- | |||
| On || Boolean || Returns whether the Chute Bin is turned on. (0 for off, 1 for on) | |||
|- | |||
| RequiredPower || Integer || Returns the current amount of power, required by the Chute Bin, in Watts. | |||
|} | |||
=== Chute Outlet === | |||
==== Logic Parameters ==== | |||
These are all parameters, that can be written to with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them. | |||
{| class="wikitable" | |||
|- | |||
! Parameter Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Opens the Chute Outlet once, when set to 1. | |||
|- | |||
| Lock || Boolean || Locks the Chute Outlet, when set to 1. Unlocks it, when set to 0. | |||
|} | |||
==== Logic Outputs ==== | |||
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Returns whether the Chute Outlet is open. (0 for closed, 1 for open) This only returns 1 briefly, when the Chute Outlet opens. | |||
|- | |||
| Lock || Boolean || Returns whether the Chute Outlet is locked. (0 for unlocked, 1 for locked) | |||
|- | |||
| ImportQuantity || Integer || Returns the amount of items, the Chute Outlet is holding, in grams. | |||
|- | |||
| ImportSlotOccupant || Boolean || Returns whether the Chute Outlet is holding an item. (0 for no item, 1 for holding an item) | |||
|} | |||
=== Chute Inlet === | |||
==== Logic Parameters ==== | |||
This device does not have any logic parameters and can not be selected with a [[Kit_(Logic_I/O)#Logic_Writer|Logic Writer]] or a [[Kit_(Logic_I/O)#Batch_Writer|Batch Writer]]. | |||
==== Logic Outputs ==== | |||
These are all parameters, that can be read with a [[Kit_(Logic_I/O)#Logic_Reader|Logic Reader]]. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them. | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| ImportQuantity || Integer || Returns the amount of items, the Chute Inlet is holding, in grams. | |||
|- | |||
| ImportSlotOccupant || Boolean || Returns whether the Chute Inlet is holding an item. (0 for no item, 1 for holding an item) | |||
|} | |||
Revision as of 17:01, 25 March 2018
![]() | |
| Properties | |
|---|---|
| Stacks | Yes (10) |
| Recipe | |
| Created With | Autolathe, Fabricator, Hydraulic Pipe Bender |
| Cost | 1g Iron* |
| Operation | |
|---|---|
| Construction | |
| Placed with | {{{placed_with_item}}} |
| Placed on | {{{placed_on_grid}}} |
Description
Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network.
Recipes
| Manufactory | Materials | Time | Energy |
|---|---|---|---|
| Autolathe | 3g Iron | 5 | 500 |
| Fabricator | 1g Iron | 1 | 500 |
| Hydraulic Pipe Bender | 1g Iron | 5 | 500 |
| Recycler | 1,5g Iron | 5 | 1000 |
Logic Properties
These are all logic properties of the devices.
Chute Bin
Logic Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
| Parameter Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Opens the Chute Bin, when set to 1. Closes it, when set to 0. |
| On | Boolean | Turns the Chute Bin on, when set to 1. Turns it off, when set to 0. |
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Power | Boolean | Returns whether the Chute Bin is turned on. (0 for off, 1 for on) (Identical to "On" output. This might be intended to output whether the device is receiving power or not.) |
| Open | Boolean | Returns whether the Chute Bin is open. (0 for closed, 1 for open) |
| Error | Boolean | Returns whether the Chute Bin is flashing an error. (0 for no error, 1 for flashing an error) |
| On | Boolean | Returns whether the Chute Bin is turned on. (0 for off, 1 for on) |
| RequiredPower | Integer | Returns the current amount of power, required by the Chute Bin, in Watts. |
Chute Outlet
Logic Parameters
These are all parameters, that can be written to with a Logic Writer or a Batch Writer. The outputs are listed in the order a Logic Writer's "VAR" setting cycles through them.
| Parameter Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Opens the Chute Outlet once, when set to 1. |
| Lock | Boolean | Locks the Chute Outlet, when set to 1. Unlocks it, when set to 0. |
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Returns whether the Chute Outlet is open. (0 for closed, 1 for open) This only returns 1 briefly, when the Chute Outlet opens. |
| Lock | Boolean | Returns whether the Chute Outlet is locked. (0 for unlocked, 1 for locked) |
| ImportQuantity | Integer | Returns the amount of items, the Chute Outlet is holding, in grams. |
| ImportSlotOccupant | Boolean | Returns whether the Chute Outlet is holding an item. (0 for no item, 1 for holding an item) |
Chute Inlet
Logic Parameters
This device does not have any logic parameters and can not be selected with a Logic Writer or a Batch Writer.
Logic Outputs
These are all parameters, that can be read with a Logic Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| ImportQuantity | Integer | Returns the amount of items, the Chute Inlet is holding, in grams. |
| ImportSlotOccupant | Boolean | Returns whether the Chute Inlet is holding an item. (0 for no item, 1 for holding an item) |
