Basic Chutes: Difference between revisions
More actions
Ipottinger (talk | contribs) Correct name to Constructionkit (Chutes) |
moved stuff from construcionkit (chutes) here |
||
| Line 1: | Line 1: | ||
{{Itembox | |||
| image = [[File:ItemKitChute.png]] | |||
| name = Kit (Chutes) | |||
| createdwith = [[Autolathe]], [[Fabricator]], [[Hydraulic Pipe Bender]] | |||
| cost = 1g [[Iron]]* | |||
| stacks = 10 | |||
}} | |||
{{Structurebox | |||
| name = Chute | |||
| placed_with_item = [[Kit (Chutes)]] | |||
| placed_on_grid = Small Grid | |||
| decon_with_tool1 = [[Wrench]] | |||
| item_rec1 = [[Kit (Chutes)]] | |||
}} | |||
= Chute = | |||
== Description == | |||
Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network. | |||
== Recipes ==<!--T:3--> | |||
{{Recipe | |||
|{{Recipe/row |machine = Autolathe |mats = 3g [[Iron]] |time = 5 |energy = 500}} | |||
|{{Recipe/row |machine = Fabricator |mats = 1g [[Iron]] |time = 1 |energy = 500}} | |||
|{{Recipe/row |machine = Hydraulic Pipe Bender |mats = 1g [[Iron]] |time = 5 |energy = 500}} | |||
|{{Recipe/row |machine = Recycler |mats = 1,5g [[Iron]] |time = 5 |energy = 1000}} | |||
}} | |||
= Chute Bin = | |||
{{Data Network Header}} | |||
{{Data Parameters}} | |||
{| class="wikitable" | |||
|- | |||
! Parameter Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Opens the Chute Bin, when set to 1. Closes it, when set to 0. | |||
|- | |||
| On || Boolean || Turns the Chute Bin on when set to 1. Turns it off, when set to 0. | |||
|} | |||
{{Data Outputs}} | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| Power || Boolean || Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes) | |||
|- | |||
| Open || Boolean || Returns whether the Chute Bin is open. (0 for no, 1 for yes) | |||
|- | |||
| Error || Boolean || Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes) | |||
|- | |||
| On || Boolean || Returns whether the Chute Bin is turned on. (0 for no, 1 for yes) | |||
|- | |||
| RequiredPower || Integer || Returns the current amount of power, required by the Chute Bin, in watts. | |||
|} | |||
= Chute Outlet = | |||
{{Data Network Header}} | |||
{{Data Parameters}} | |||
{| class="wikitable" | |||
|- | |||
! Parameter Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Opens the Chute Outlet when set to 1. | |||
|- | |||
| Lock || Boolean || Locks the Chute Outlet when set to 1. Unlocks it, when set to 0. | |||
|} | |||
{{Data Outputs}} | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| Open || Boolean || Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens. | |||
|- | |||
| Lock || Boolean || Returns whether the Chute Outlet is locked. (0 for no, 1 for yes) | |||
|- | |||
| ImportQuantity || Integer || Returns the number of items, the Chute Outlet is holding, in grams. | |||
|- | |||
| ImportSlotOccupant || Boolean || Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes) | |||
|} | |||
= Chute Inlet = | |||
{{Data Network Header}} | |||
{{Data Parameters|empty}} | |||
{{Data Outputs}} | |||
{| class="wikitable" | |||
|- | |||
! Output Name !! Data Type !! Description | |||
|- | |||
| ImportQuantity || Integer || Returns the number of items, the Chute Inlet is holding, in grams. | |||
|- | |||
| ImportSlotOccupant || Boolean || Returns whether the Chute Inlet is holding an item. (0 for no, 1 for yes) | |||
|} | |||
Revision as of 17:57, 15 September 2018
![]() | |
| Properties | |
|---|---|
| Stacks | Yes (10) |
| Recipe | |
| Created With | Autolathe, Fabricator, Hydraulic Pipe Bender |
| Cost | 1g Iron* |
| Operation | |
|---|---|
| Construction | |
| Placed with | Kit (Chutes) |
| Placed on | Small Grid |
| Stage 1 | |
| Deconstruction | |
| Deconstructed with | Wrench |
| Item received | Kit (Chutes) |
Chute
Description
Used to transport items. The Kit can be used to create 7 different variants, some of them are able to connect to power and logic network.
Recipes
| Manufactory | Materials | Time | Energy |
|---|---|---|---|
| Autolathe | 3g Iron | 5 | 500 |
| Fabricator | 1g Iron | 1 | 500 |
| Hydraulic Pipe Bender | 1g Iron | 5 | 500 |
| Recycler | 1,5g Iron | 5 | 1000 |
Chute Bin
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Opens the Chute Bin, when set to 1. Closes it, when set to 0. |
| On | Boolean | Turns the Chute Bin on when set to 1. Turns it off, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Power | Boolean | Returns whether the Chute Bin is turned on and receives power. (0 for no, 1 for yes) |
| Open | Boolean | Returns whether the Chute Bin is open. (0 for no, 1 for yes) |
| Error | Boolean | Returns whether the Chute Bin is flashing an error. (0 for no, 1 for yes) |
| On | Boolean | Returns whether the Chute Bin is turned on. (0 for no, 1 for yes) |
| RequiredPower | Integer | Returns the current amount of power, required by the Chute Bin, in watts. |
Chute Outlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Opens the Chute Outlet when set to 1. |
| Lock | Boolean | Locks the Chute Outlet when set to 1. Unlocks it, when set to 0. |
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| Open | Boolean | Returns whether the Chute Outlet is open. (0 for no, 1 for yes) This only returns 1 briefly, when the Chute Outlet opens. |
| Lock | Boolean | Returns whether the Chute Outlet is locked. (0 for no, 1 for yes) |
| ImportQuantity | Integer | Returns the number of items, the Chute Outlet is holding, in grams. |
| ImportSlotOccupant | Boolean | Returns whether the Chute Outlet is holding an item. (0 for no, 1 for yes) |
Chute Inlet
Data Network Properties
These are all Data Network properties of this device.
Data Parameters
These are all parameters that can be written with a Logic Writer, Batch Writer, or Integrated Circuit (IC10), and can be read with a Logic Reader, Batch Reader, or Integrated Circuit (IC10).
| Parameter Name | Data Type | Access | Value | Description | |
|---|---|---|---|---|---|
Data Outputs
These are all parameters, that can be read with a Logic Reader or a Slot Reader. The outputs are listed in the order a Logic Reader's "VAR" setting cycles through them.
| Output Name | Data Type | Description |
|---|---|---|
| ImportQuantity | Integer | Returns the number of items, the Chute Inlet is holding, in grams. |
| ImportSlotOccupant | Boolean | Returns whether the Chute Inlet is holding an item. (0 for no, 1 for yes) |
