Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Gas

From Stationeers Wiki
Revision as of 14:36, 1 August 2023 by MCZarin (talk | contribs)

<languages/> <translate>

This is a disambiguation page, which lists pages which may be the intended target. If a page link referred you here, please consider editing it to point directly to the intended page.
  • stationpedia has simple phase diagrams for all Gasses, a more complex phase change diagram can be located Here

Gas may refer to:

</translate>


Gases

Name Filter Color Molar Heat Capacity (J) Latent Heat (kJ) Solid Temperature (K/°C) Boiling Point at 100 kPa Minimum Condensation (kPa at (K/°C)) Maximum Liquid Temperature ((K/°C) at kPa)
Carbon Dioxide (CO2) Gray 28.2 0.6 218 / -55.3 N/A 517 at 218 / -55.3 265 / -8.1 at 6000
Nitrogen (N2) Black 20.6 0.5 40 / -233 75 / -198 6.3 at 40 / 233 190 / -83 at 6000
Nitrous Oxide (N2O) Green 37.2 4 252 / -21 N/A 800 at 252 / -21 431 / 158 at 2000
Oxygen (O2) White 21.1 0.8 56.4 / -217 90 / -183 6.3 at 56.4 / -217 162 / -111 at 6000
Pollutant (X) Yellow 24.8 2 173 / -99.8 N/A 1800 at 173 / -99.8 425 / 152 at 6000
Volatiles (H2) Red 20.4 1 81.6 / -192 112 / -162 6.3 at 81.6 / -192 195 / -78.1 at 6000
Water (H20) Blue 72 8 273 / 0 373 / 100 6.3 at 273 / 0 643 / 370 at 6000

* phase change has been added to the game system and most gasses now have an associated [Liquid] and a pure Solids phase .

* the following exist only in solid state and have no gaseous form: Charcoal, Coal, Silicon, Iron, Copper, Nickel, Silver, Gold, Lead, Uranium

Mixtures

Name Contents Tank Color Notes
Fuel 67% H2, 33% O2 Orange Autoignition at 573.15 K / 300 °C
HydroNox 50% H2, 50% N2O N/A Autoignition at 323.15 K / 50 °C
Air 75% N2, 25% O2 White 16 kPa Partial Pressure O2 minimum is required for human player breathing. Hyperoxia is not simulated.

Simulation Mechanics

  • Ideal gas law (PV=nRT) is simulated.
  • Thermal conductivity is not simulated. (f.e. heat is transferred at the same fixed rate for all substances; structures and devices are ignored)
  • Thermal radiation is simulated. (caveat: radiated infrared is not absorbed by nearby objects)
  • Phase change is simulated. (caveat: simplified and with fixed temperature for solid state)
  • Fluid dynamics are not simulated. (caveat: thermal convection is partially simulated)
  • Each environment grid cube acts as a single point and each connected pipe network acts as a single point.
  • All pumps/mixer also act as a check valve.
  • Gas stoichiometry is partially utilized. Some reactions do not reflect real-life.
  • Gas pressure determines liquid pressure; gravity/height is ignored.
  • Pipes have arbitrary stress value determined by amount of non-correct phase of substance within them (liquid in a gas pipe).
  • [bug?] Liquid temperature is controlled by gas temperature. (if no gas present, liquid heater will not function)